Sub Categories
LMC Metalurgicall of precision
Address
Calle 109 (1º de Agosto de 1806) Nº 4945
Villa Ballester, Pdo de Gral. San Martín
Phones
+54 11 4738 2599 / 4767 4362 / 4768 9785
Simples
Pumps LMC series 10, are of the type to vanes, construction balanced hydraulically, fixed displacement, internal drainage. They are possible to be used with several types of fluid and with speed motors it fixes or variable.
General data (Click to expand)
Model
Performance
Installation
Is recommendable connects direct, coaxial and flexible between motor and pump. If an indirect control imposes radial loads and/or axial consúltenos.
If special position is required to specify it in the order.
In the first beginning, if the pump has not been fattened must bleed the air, relaxing a racor of the line of exit near the pump until the fluid flows or installing a valve of air purge. If it is required to use other consult us special fluids or additional information.
Pumps LMC series 20, are of the type to vanes, construction balanced hydraulically, fixed displacement, internal drainage. They are possible to be used with several types of fluid and with speed motors it fixes or variable.
General data (Click to expand)
Model
Performance
Installation
Is recommendable connects direct, coaxial and flexible between motor and pump. If an indirect control imposes radial loads and/or axial consúltenos.
If special position is required to specify it in the order.
In the first beginning, if the pump has not been fattened must bleed the air, relaxing a racor of the line of exit near the pump until the fluid flows or installing a valve of air purge. If it is required to use other consult us special fluids or additional information.
Pumps LMC series 20 P are of the type to vanes, construction balanced hydraulically, fixed displacement, internal drainage. They are possible to be used with several types of fluid and with speed motors it fixes or variable.
General data (Click to expand)
Model
Technical data - Model code - Performances
The engineering datas and the code of model are similar to those of the pump series 20. The total efficiencies of the pump also are given by the tables corresponding to the pump series 20; but the yields of the primary volume, based on the volume of the pump and the calibrated orifice, are given in the graph.Installation
Is recommendable connects direct coaxial and flexible between motor and pump. If an indirect control imposes radial loads and/or axial consult us.
If special position is required to specify it in the order.
The installation position is indifferent. In the first beginning, if the pump has not been fattened must bleed the air, relaxing a racor of the line of exit near the pump until the fluid flows or installing a valve of air purge. If it is required to use other consult us special fluids or additional information
This pump brings built-in this valve which separates the main cuadal in two; the primary one, which approximately remains constant with the variations of speed and pressure; used generally in control mechanisms; and the secondary one; subject to these variations which is used for other movements. The circuit of the primary volume comes provided with valve of adjustable built-in lightening.